Guy wire size chart11/12/2023 ![]() For the end user, the answer is just a few clicks away. The customization is set up by a knowledgeable engineer in the company. An important feature of all the Toolbox programs is that the programs are easily customized to the materials and practices of the using company. Most programs can be readily used by a technician or engineer without even first consulting the manual. The Toolbox programs are designed for extreme user ease. This tool was originally developed as part of the DSTAR Engineering Toolbox. changes of conductor size at a tangent pole, and.dead-ending of certain conductors at a tangent pole with other conductors continuing on (such as a transition from a three-phase feeder to a single-phase feeder, with two phases terminating at the pole),.corner dead-ends (if the lines are perpendicular),.The Guy Tension Analyzer, with appropriate application techniques, can be used to perform guy calculations for the following special situations: The sidewalk configuration accommodates ten lines (angle or dead-end) with a single guy. The tool provides complete flexibility to connect any guy to any anchor. 1.1 Anchor means an anchor owned by NES which is a device to reinforce the pole to which it is attached by a guy wire. Four Core Aluminium Conductor 5.Aluminium Corrugted Cable 6.In the standard and span guy configurations, up to ten lines (ten lines in each direction for angle poles) can be accommodated, together with up to ten tap lines terminating at an arbitrary angle with respect to the main line (feature not supported with sidewalk configuration), as well as five guy wires and anchors. Customers' satisfaction is the best return for staffa of our Company.ġ.High Quality Aluminum Alloy 2.Single Coe Aluminium Conductor 3. The after-sale service department provides series of before-sale,selling and after-sale, which solve the worries behind for customers and provide complete and rapid service for customers. To providefirst-rate products and service for society is the pursuit of staffs of our Company forever. Our Honor We got trust and praise from all customers by outstanding quality and good reputation. The company introduced the world's advanced level wire & cable production and testing equipment, such as DV-6E spectrum analyzer, online micro pore impurity tester, etc.Īdvanced Testing Equipment Guarantee High Quality Production Galvanizes steel wire strand,3/8inch guy wire,ASTM 475A standard: Galvanizes steel wire strand,3/8inch guy wire,ASTM 475A, with fumigated drums. Otherwise, the force on the operating conductors will be unbalanced after connectors are pressed, the connecting tube should be plated ny moistureproof paint in order to protect from corroding.Ģ.4 Under installation, the arc downing stress of all the conductors at home distance ot the ground and across building can be 10-15% higher than regular tension.ģ.1 Any crush or bump should be avoided during handling and transportation of the product.ģ.2 The cable drum is not allowed to be placed with one flange up and the other down during transportation and storage of the products.ģ.2 A moisture-proof measure should be taken during storage of the productģ.4 Corrugated aluminium pipe busbar, made of aluminium wires or aluminium alloy wires stranded around aluminium pipe. ![]() ![]() The cables have excellent advantages of high strength, large current carrying capacity and good catenary property as well as wear-resistance, anti-crush and corrosion-froof with simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity.Ģ.1 The permissible long-time operating temperature for aerial conductor is 70.Ģ.2 The circumstance that long distance rare climate and ice coverage rare occurring in heavy ice area, the most biggest stress of cable at the lowest arc downing point should not exceed 60% of the distructive power at a short time.Ģ.3 When connecting conductors, the conductor near to the connecting tube can`t be prominient. They have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.ĪAAC and AACSR have been widely used in power transmission lines with various voltage levels, and also used in power lines across great rivers, heavy ice area, etc. Overhead conductor covers a serious of conductors such as AAC(All Aluminium Conductor), ACSR(Aluminium Conductor Steel Reinforced ), AAAC(Aluminium Alloy Conductor ), BCC(Bare Copper Conductor), ACS(Aluminium Clad Steel Conductor).ĪAC and ACSR have been widely used in power transmission lines with various voltage levels. The conductors are used in overhead power line. 3 Inch / 8 Inch ACSR Guy Wire, Galvanized Steel Wire High Strengh
0 Comments
Leave a Reply.AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |